UPS (inverter, sine, for boiler, PF 1, wall-mounted) ExeGate IdealSine SR-600.LCD.2SH

UPS (inverter, sine, for boiler, PF 1, wall-mounted) ExeGate IdealSine SR-600.LCD.2SH
UPS (inverter, sine, for boiler, PF 1, wall-mounted) ExeGate IdealSine SR-600.LCD.2SH
UPS (inverter, sine, for boiler, PF 1, wall-mounted) ExeGate IdealSine SR-600.LCD.2SH
UPS (inverter, sine, for boiler, PF 1, wall-mounted) ExeGate IdealSine SR-600.LCD.2SH
UPS (inverter, sine, for boiler, PF 1, wall-mounted) ExeGate IdealSine SR-600.LCD.2SH
UPS (inverter, sine, for boiler, PF 1, wall-mounted) ExeGate IdealSine SR-600.LCD.2SH
UPS (inverter, sine, for boiler, PF 1, wall-mounted) ExeGate IdealSine SR-600.LCD.2SH
UPS (inverter, sine, for boiler, PF 1, wall-mounted) ExeGate IdealSine SR-600.LCD.2SH
UPS (inverter, sine, for boiler, PF 1, wall-mounted) ExeGate IdealSine SR-600.LCD.2SH
UPS (inverter, sine, for boiler, PF 1, wall-mounted) ExeGate IdealSine SR-600.LCD.2SH
ModificationP/NEAN
IdealSine SR-600EX2959924895205161634
IdealSine SR-600/DT 1226 (12V, 26Ah)EX2973804895205173606
IdealSine SR-600/HRL 12-26 (12V, 26Ah)EX2973814895205173613
IdealSine SR-600/DT 1233 (12V, 33Ah)EX2973824895205173620
IdealSine SR-600/HRL 12-33 (12V, 33Ah)EX2973834895205173637
IdealSine SR-600/DT 1240 (12V, 40Ah)EX2973844895205173644
IdealSine SR-600/HR 12-40 (12V, 40Ah)EX2973854895205173651
IdealSine SR-600/HRL 12-45 (12V, 45Ah)EX2973864895205173668
IdealSine SR-600/HRL 12-55 (12V, 55Ah)EX2973874895205173675
IdealSine SR-600/DTM 1255 (12V, 55Ah)EX2973884895205173682
IdealSine SR-600/DT 1265 (12V, 65Ah)EX2973894895205173699
IdealSine SR-600/HR 12-65 (12V, 65Ah)EX2973904895205173705
IdealSine SR-600/DT 1275 (12V, 75Ah)EX2973914895205173712
IdealSine SR-600/HRL 12-75 (12V, 75Ah)EX2973924895205173729
IdealSine SR-600/HRL 12-80 (12V, 80Ah)EX2973934895205173736
IdealSine SR-600/HRL 12-90 (12V, 90Ah)EX2973944895205173743
IdealSine SR-600/DT 12100 (12V, 100Ah)EX2973954895205173750
IdealSine SR-600/HRL 12-100 (12V, 100Ah)EX2973964895205173767
IdealSine SR-600/DT 12120 (12V, 120Ah)EX2973974895205173774
IdealSine SR-600/HRL 12-120 (12V, 120Ah)EX2973984895205173781
IdealSine SR-600/DT 12150 (12V, 150Ah)EX2974004895205173804
IdealSine SR-600/DT 12200 (12V, 200Ah)EX2974024895205173828


UPS (inverter, sine, for boiler, PF 1, wall-mounted) ExeGate IdealSine SR-600.LCD.2SH
UPS (inverter, sine, for boiler, PF 1, wall-mounted) ExeGate IdealSine SR-600.LCD.2SH
UPS (inverter, sine, for boiler, PF 1, wall-mounted) ExeGate IdealSine SR-600.LCD.2SH
UPS (inverter, sine, for boiler, PF 1, wall-mounted) ExeGate IdealSine SR-600.LCD.2SH
UPS (inverter, sine, for boiler, PF 1, wall-mounted) ExeGate IdealSine SR-600.LCD.2SH
UPS (inverter, sine, for boiler, PF 1, wall-mounted) ExeGate IdealSine SR-600.LCD.2SH
UPS (inverter, sine, for boiler, PF 1, wall-mounted) ExeGate IdealSine SR-600.LCD.2SH
UPS (inverter, sine, for boiler, PF 1, wall-mounted) ExeGate IdealSine SR-600.LCD.2SH
UPS (inverter, sine, for boiler, PF 1, wall-mounted) ExeGate IdealSine SR-600.LCD.2SH
UPS (inverter, sine, for boiler, PF 1, wall-mounted) ExeGate IdealSine SR-600.LCD.2SH
Line-interactive UPS IdealSine series have a high power density (W= VA), provide a sinusoidal voltage of strictly regular shape (pure sine wave) at the output, which makes them an ideal choice for power supply of boilers, pumps, medical and other equipment demanding on the quality of supply voltage.

Specification

TypeUPS
Type of UPSOff-Grid
Full power capacity, VA600
Active power, W600
Power Factor (PF)1
Efficiency (AC mode), %> 95
Output connector2xSchuko
Input
Input connectionEuroplug with grounding. Detachable cable.
Cable length, m1,2
Nominal input voltage,V220±5%
Input voltage range for mains operation, V170-270
Input frequency, Hz45-65
Output
Nominal output voltage, V220 ±5% for battery mode;170V-270 for AC mode
Output frequency, Hz50/60±0.5 for battery mode;45-65 for AC mode
Waveform typePure sine wave
Protection
Surge Protection at line modeShutdown after 5 min when the load is > 110%
Batteries and battery life
Nominal input voltage,V12
Battery typeSealed lead-acid battery, maintenance-free
Battery capacity and battery quantity, Ah26-200 (must be purchased additionally)
Cold startYes
Charge Current20
Battery cable length, m0,7
TerminalsM6
Indicators and signals
Indicator typeLCD
Other parameters
Operating Temperature0-40 C
Storage Tempetature- 15 - 45 C
Operating Relatie Humidity10-90%
Cabinet colorBlack
Cabinet madeSteel
Dimensions, mm330x210x105
Package dimensions, mm390x260x155
Net weight, kg3
Gross weight, kg3,94
Delivery setUPS, bracket, battery cables, Power cable, user manual